Refractometer Calibration

Chemical calibration for specified ANAB instruments plus currently represented analyzer items.

Request Quotation

SK Calibration Laboratory

Chemical Calibration / Refractometer Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

This service is discoverable from the registry, but no exact verified accredited range row is assigned to this capability page.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
12
Service Location Summary
Permanent, Site
Accreditation Programs
TISI 0261

Capability overview

Refractometer calibration overview

Refractometer Calibration support is built from SK's existing Chemical capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
chemical
Accreditation
TISI 0261
Range mapping
parameter-filtered
Range summary
See accredited capability table on this page.
Method summary
Accredited chemical calibration procedure for pH, conductivity, TDS, turbidity and represented analyzer instruments.

Accredited Scope

Verified range evidence for this capability

Only verified source rows associated with this selected capability mapping are shown. Instrument-family applicability must be confirmed before claiming accreditation.

Program

TISI 0261

6 verified evidence rows

Official SectionChemical / PermanentShow 6 Evidence Rows

Parameter / Equipment

Refractometer

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

6 Range Rows

Range

10 %Brix

CMC / Expanded Uncertainty

0.13 %Brix

Range

20 %Brix

CMC / Expanded Uncertainty

0.13 %Brix

Range

30 %Brix

CMC / Expanded Uncertainty

0.13 %Brix

Range

40 %Brix

CMC / Expanded Uncertainty

0.13 %Brix

Range

50 %Brix

CMC / Expanded Uncertainty

0.13 %Brix

Range

60 %Brix

CMC / Expanded Uncertainty

0.13 %Brix

Evidence DetailsShow
Source Row 1
10 %Brix / 0.13 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
13
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
20 %Brix / 0.13 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
13
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
30 %Brix / 0.13 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
13
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
40 %Brix / 0.13 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
13
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 5
50 %Brix / 0.13 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
13
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 6
60 %Brix / 0.13 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
13
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Program

TISI 0261 — Site

6 verified evidence rows

Official SectionChemical / SiteShow 6 Evidence Rows

Parameter / Equipment

Refractometer

Type / Subtype
General
Accreditation program
TISI 0261 — Site
Service Location
TISI 0261 — Site

6 Range Rows

Range

10 %Brix

CMC / Expanded Uncertainty

0.20 %Brix

Range

20 %Brix

CMC / Expanded Uncertainty

0.20 %Brix

Range

30 %Brix

CMC / Expanded Uncertainty

0.20 %Brix

Range

40 %Brix

CMC / Expanded Uncertainty

0.20 %Brix

Range

50 %Brix

CMC / Expanded Uncertainty

0.20 %Brix

Range

60 %Brix

CMC / Expanded Uncertainty

0.20 %Brix

Evidence DetailsShow
Source Row 1
10 %Brix / 0.20 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
23
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 2
20 %Brix / 0.20 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
23
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 3
30 %Brix / 0.20 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
23
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 4
40 %Brix / 0.20 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
23
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 5
50 %Brix / 0.20 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
23
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 6
60 %Brix / 0.20 %Brix
Method
Direct measurement with Certified reference material (CRM)
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
23
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Refractometer Calibration FAQ

Is refractometer calibration accredited?+

Accreditation may apply under TISI 0261 when the instrument, range and method are included in the current official scope.

What information is needed for a refractometer quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.