TDS Meter Calibration

Chemical calibration for specified ANAB instruments plus currently represented analyzer items.

Request Quotation

SK Calibration Laboratory

Chemical Calibration / TDS Meter Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

This service is discoverable from the registry, but no exact verified accredited range row is assigned to this capability page.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
6
Service Location Summary
On-site available
Accreditation Programs
ANAB AC-3279

Capability overview

TDS Meter calibration overview

TDS Meter Calibration support is built from SK's existing Chemical capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
chemical
Accreditation
ANAB AC-3279
Range mapping
parameter-filtered
Range summary
See accredited capability table on this page.
Method summary
Accredited chemical calibration procedure for pH, conductivity, TDS, turbidity and represented analyzer instruments.

Accredited Scope

Verified range evidence for this capability

Only verified source rows associated with this selected capability mapping are shown. Instrument-family applicability must be confirmed before claiming accreditation.

Program

ANAB AC-3279

6 verified evidence rows

Official SectionChemical QuantitiesShow 6 Evidence Rows

Parameter / Equipment

TDS Meter

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

6 Range Rows

Range

10 mg/L

CMC / Expanded Uncertainty

0.3 mg/L

Range

50 mg/L

CMC / Expanded Uncertainty

0.4 mg/L

Range

100 mg/L

CMC / Expanded Uncertainty

0.8 mg/L

Range

500 mg/L

CMC / Expanded Uncertainty

4.1 mg/L

Range

1 000 mg/L

CMC / Expanded Uncertainty

7.9 mg/L

Range

1 500 mg/L

CMC / Expanded Uncertainty

12 mg/L

Evidence DetailsShow
Source Row 1
10 mg/L / 0.3 mg/L
Method
SK-WI-004 by comparison with certified values of certified reference materials.
Source Group
TDS Meter (~25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
~25 °C
Service Location
On-site available
Reference Equipment
Source Row 2
50 mg/L / 0.4 mg/L
Method
SK-WI-004 by comparison with certified values of certified reference materials.
Source Group
TDS Meter (~25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
~25 °C
Service Location
On-site available
Reference Equipment
Source Row 3
100 mg/L / 0.8 mg/L
Method
SK-WI-004 by comparison with certified values of certified reference materials.
Source Group
TDS Meter (~25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
~25 °C
Service Location
On-site available
Reference Equipment
Source Row 4
500 mg/L / 4.1 mg/L
Method
SK-WI-004 by comparison with certified values of certified reference materials.
Source Group
TDS Meter (~25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
~25 °C
Service Location
On-site available
Reference Equipment
Source Row 5
1 000 mg/L / 7.9 mg/L
Method
SK-WI-004 by comparison with certified values of certified reference materials.
Source Group
TDS Meter (~25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
~25 °C
Service Location
On-site available
Reference Equipment
Source Row 6
1 500 mg/L / 12 mg/L
Method
SK-WI-004 by comparison with certified values of certified reference materials.
Source Group
TDS Meter (~25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
~25 °C
Service Location
On-site available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

TDS Meter Calibration FAQ

Is tds meter calibration accredited?+

Accreditation may apply under ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a tds meter quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.