S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Capability Detail

Turbidity Meter Calibration

Chemical calibration for specified ANAB instruments plus currently represented analyzer items.

Request Quotation

SK Calibration Laboratory

Chemical Calibration / Turbidity Meter Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

This service is discoverable from the registry, but no exact verified accredited range row is assigned to this capability page.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
10
Service Location Summary
On-site available
Accreditation Programs
ANAB AC-3279

Capability overview

Turbidity Meter calibration overview

Turbidity Meter Calibration support is built from SK's existing Chemical capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
chemical
Accreditation
ANAB AC-3279
Range mapping
parameter-filtered
Range summary
See accredited capability table on this page.
Method summary
Accredited chemical calibration procedure for pH, conductivity, TDS, turbidity and represented analyzer instruments.

Accredited Scope

Verified range evidence for this capability

Only verified source rows associated with this selected capability mapping are shown. Instrument-family applicability must be confirmed before claiming accreditation.

Program

ANAB AC-3279

10 verified evidence rows

Official SectionChemical QuantitiesShow 10 Evidence Rows

Parameter / Equipment

Turbidity Meter

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

10 Range Rows

Range

1 NTU

CMC / Expanded Uncertainty

0.02 NTU

Range

10 NTU

CMC / Expanded Uncertainty

0.13 NTU

Range

20 NTU

CMC / Expanded Uncertainty

0.18 NTU

Range

50 NTU

CMC / Expanded Uncertainty

0.37 NTU

Range

100 NTU

CMC / Expanded Uncertainty

1.2 NTU

Range

500 NTU

CMC / Expanded Uncertainty

4.3 NTU

Range

800 NTU

CMC / Expanded Uncertainty

6.9 NTU

Range

1 000 NTU

CMC / Expanded Uncertainty

8.4 NTU

Range

2 000 NTU

CMC / Expanded Uncertainty

19 NTU

Range

4 000 NTU

CMC / Expanded Uncertainty

42 NTU

Evidence DetailsShow
Source Row 1
1 NTU / 0.02 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 2
10 NTU / 0.13 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 3
20 NTU / 0.18 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 4
50 NTU / 0.37 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 5
100 NTU / 1.2 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 6
500 NTU / 4.3 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 7
800 NTU / 6.9 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 8
1 000 NTU / 8.4 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 9
2 000 NTU / 19 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment
Source Row 10
4 000 NTU / 42 NTU
Method
SK-WI-005 by comparison with certified values of certified reference materials.
Source Group
Turbidity Meter (20 to 25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
20 °C to 25 °C
Service Location
On-site available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Turbidity Meter Calibration FAQ

Is turbidity meter calibration accredited?+

Accreditation may apply under ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a turbidity meter quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.