Vernier Caliper
Typical Applications
- Production
- Laboratory
- Quality Control
Calibration Availability
Available under the accredited scope where applicable.
Scope Detail
บริการสอบเทียบเครื่องมือวัดมิติสำหรับงานตรวจสอบคุณภาพ งานผลิต งานซ่อมบำรุง และห้องปฏิบัติการ
SK Calibration Laboratory
Reliable dimensional calibration support for inspection, production and quality-control applications.
Supported Instruments
Instrument families commonly submitted for dimension calibration and related measurement services.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Capability Summary
Accreditation
TISI 0261 covers the verified caliper, micrometer, thickness gauge, bore gauge, dial gauge and dial test indicator rows. ANAB AC-3279 covers only the verified height gauge, steel ruler, steel tape measure and textile tape measure rows; Dimension coverage differs by instrument family.
Measurement capability
Official dimensional range rows are separated by instrument family and accreditation. Capability cards and detail tables do not inherit all parent Dimension badges.
Traceability
Calibration results are supported by traceable reference standards, controlled procedures and certificate review to support maintenance, QA and audit documentation.
Certificate
Calibration certificates are provided after completion of service to support quality systems, maintenance records and customer audit requirements.
Accredited Scope
Verified ranges and expanded measurement uncertainty from the applicable accredited scope.
Program
12 verified evidence rows
Parameter / Equipment
3 Range Rows
Range
0 mm to 150 mm
CMC / Expanded Uncertainty
15 µm
Range
> 150 mm to 200 mm
CMC / Expanded Uncertainty
16 µm
Range
> 200 mm to 300 mm
CMC / Expanded Uncertainty
18 µm
Parameter / Equipment
1 Range Rows
Range
0 mm to 25 mm
CMC / Expanded Uncertainty
1.5 µm
Parameter / Equipment
1 Range Rows
Range
0 mm to 13 mm
CMC / Expanded Uncertainty
5.9 µm
Parameter / Equipment
2 Range Rows
Range
0 mm to 10 mm
CMC / Expanded Uncertainty
1.4 µm
Range
> 10 mm to 25 mm
CMC / Expanded Uncertainty
5.9 µm
Parameter / Equipment
1 Range Rows
Range
0 mm to 2 mm
CMC / Expanded Uncertainty
4.0 µm
Parameter / Equipment
3 Range Rows
Range
0 mm to 10 mm
CMC / Expanded Uncertainty
4.0 µm
Range
> 10 mm to 25 mm
CMC / Expanded Uncertainty
4.1 µm
Range
> 25 mm to 50 mm
CMC / Expanded Uncertainty
4.5 µm
Parameter / Equipment
1 Range Rows
Range
0 mm to 1.5 mm
CMC / Expanded Uncertainty
4.6 µm
Program
33 verified evidence rows
Parameter / Equipment
3 Range Rows
Range
Up to 300 mm
CMC / Expanded Uncertainty
0.015 mm
Range
(>300 to 600) mm
CMC / Expanded Uncertainty
0.016 mm
Range
(>600 to 1 000) mm
CMC / Expanded Uncertainty
0.02 mm
Parameter / Equipment
2 Range Rows
Range
Up to 1 000 mm
CMC / Expanded Uncertainty
0.031 mm
Range
(>1 000 to 2 000) mm
CMC / Expanded Uncertainty
0.058 mm
Parameter / Equipment
14 Range Rows
Range
Up to 1 m
CMC / Expanded Uncertainty
0.021 mm
Range
(>1 to 2) m
CMC / Expanded Uncertainty
0.031 mm
Range
(>2 to 3) m
CMC / Expanded Uncertainty
0.043 mm
Range
(>3 to 4) m
CMC / Expanded Uncertainty
0.056 mm
Range
(>4 to 5) m
CMC / Expanded Uncertainty
0.069 mm
Range
(>5 to 6) m
CMC / Expanded Uncertainty
0.082 mm
Range
(>6 to 7) m
CMC / Expanded Uncertainty
0.095 mm
Range
(>7 to 8) m
CMC / Expanded Uncertainty
0.11 mm
Range
(>8 to 9) m
CMC / Expanded Uncertainty
0.13 mm
Range
(>9 to 10) m
CMC / Expanded Uncertainty
0.14 mm
Range
(>10 to 20) m
CMC / Expanded Uncertainty
0.27 mm
Range
(>20 to 30) m
CMC / Expanded Uncertainty
0.4 mm
Range
(>30 to 40) m
CMC / Expanded Uncertainty
0.54 mm
Range
(>40 to 50) m
CMC / Expanded Uncertainty
0.67 mm
Parameter / Equipment
14 Range Rows
Range
Up to 1 m
CMC / Expanded Uncertainty
0.049 mm
Range
(>1 to 2) m
CMC / Expanded Uncertainty
0.094 mm
Range
(>2 to 3) m
CMC / Expanded Uncertainty
0.14 mm
Range
(>3 to 4) m
CMC / Expanded Uncertainty
0.19 mm
Range
(>4 to 5) m
CMC / Expanded Uncertainty
0.24 mm
Range
(>5 to 6) m
CMC / Expanded Uncertainty
0.28 mm
Range
(>6 to 7) m
CMC / Expanded Uncertainty
0.33 mm
Range
(>7 to 8) m
CMC / Expanded Uncertainty
0.37 mm
Range
(>8 to 9) m
CMC / Expanded Uncertainty
0.42 mm
Range
(>9 to 10) m
CMC / Expanded Uncertainty
0.47 mm
Range
(>10 to 20) m
CMC / Expanded Uncertainty
0.93 mm
Range
(>20 to 30) m
CMC / Expanded Uncertainty
1.4 mm
Range
(>30 to 40) m
CMC / Expanded Uncertainty
1.9 mm
Range
(>40 to 50) m
CMC / Expanded Uncertainty
2.4 mm
On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.
Calibration Process
FAQ
Typical instruments include Vernier Caliper, Dial Caliper, Digital Caliper, External Micrometer, Can Seam Micrometer, Thickness Gauge and other related instruments, depending on range, method and applicable scope.
TISI 0261 covers the verified caliper, micrometer, thickness gauge, bore gauge, dial gauge and dial test indicator rows. ANAB AC-3279 covers only the verified height gauge, steel ruler, steel tape measure and textile tape measure rows; Dimension coverage differs by instrument family.
Exact ranges, calibration points and CMC values should be confirmed against the latest official accredited scope documents and reviewed against the specific instrument details.
Please provide the instrument type, brand, model, measurement range, required calibration points, quantity, service location and required completion date.
Official Accreditation
These official accreditation documents define the verified calibration capability for this service.
Status
Accreditation Programs
RELATED SERVICES
Explore related calibration capabilities commonly requested alongside this service.
Mass and balance calibration for weighing instruments and mass standards.
Torque calibration support for hand torque tools and rotational-force measurement instruments.
Temperature calibration for industrial sensors, indicators and controlled thermal equipment, with TISI shown as the primary scope.
Ready to calibrate?
Send us your instrument information and required schedule. Our team will review the applicable capability and prepare a quotation.