S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Capability Detail

Caliper Calibration

Dimensional calibration for production, maintenance and quality inspection instruments.

Request Quotation

SK Calibration Laboratory

Dimension Calibration / Caliper Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

Rows below come from verified source rows mapped at instrument-family level. Confirm applicability to the submitted instrument before making an accreditation claim.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
3
Service Location Summary
Permanent
Accreditation Programs
TISI 0261

Capability overview

Caliper calibration overview

Caliper Calibration support is built from SK's existing Dimension capability data and applicable accredited scope information.

The official TISI 0261 Dimension row covers Vernier, Dial and Digital Calipers collectively, so this page shows the shared official caliper ranges rather than duplicating numeric CMC rows by subtype.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
dimension
Accreditation
TISI 0261
Range mapping
family-level-match
Range summary
See accredited capability table on this page.
Method summary
Methods are preserved from the official dimensional scope rows for each instrument family.

Accredited Scope

Verified range evidence for this capability

Only verified source rows associated with this selected capability mapping are shown. Instrument-family applicability must be confirmed before claiming accreditation.

Program

TISI 0261

3 verified evidence rows

Official SectionOfficial scope evidenceShow 3 Evidence Rows

Parameter / Equipment

Vernier, Dial and Digital Caliper

Type / Subtype
Vernier / Dial / Digital
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

3 Range Rows

Range

0 mm to 150 mm

CMC / Expanded Uncertainty

15 µm

Range

> 150 mm to 200 mm

CMC / Expanded Uncertainty

16 µm

Range

> 200 mm to 300 mm

CMC / Expanded Uncertainty

18 µm

Evidence DetailsShow
Source Row 1
0 mm to 150 mm / 15 µm
Method
Comparison with Gauge block
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
6
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
> 150 mm to 200 mm / 16 µm
Method
Comparison with Gauge block
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
6
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
> 200 mm to 300 mm / 18 µm
Method
Comparison with Gauge block
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
6
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Caliper Calibration FAQ

Is caliper calibration accredited?+

Accreditation may apply under TISI 0261 when the instrument, range and method are included in the current official scope.

What information is needed for a caliper quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.

Need Calibration?

Ready to calibrate Caliper?

Request Quotation