S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Capability Detail

Height Gauge Calibration

Dimensional calibration for production, maintenance and quality inspection instruments.

ANAB AC-3279
Request Quotation

SK Calibration Laboratory

Dimension Calibration / Height Gauge Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

Rows below are exact verified accredited rows associated with this capability. Values are displayed unchanged from runtime evidence.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
3
Service Location Summary
On-site available
Accreditation Programs
ANAB AC-3279

Capability overview

Height Gauge calibration overview

Height Gauge Calibration support is built from SK's existing Dimension capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
dimension
Accreditation
ANAB AC-3279
Range mapping
exact-range-match
Range summary
See accredited capability table on this page.
Method summary
Methods are preserved from the official dimensional scope rows for each instrument family.

Accredited Scope

Verified range evidence for this capability

Only exact verified source rows associated with this selected capability are shown. Official values are preserved without conversion, merging or source-group collapse.

Program

ANAB AC-3279

3 verified evidence rows

Official SectionLength – Dimensional MetrologyShow 3 Evidence Rows

Parameter / Equipment

Height Gauge

Type / Subtype
Height Gauge
Accreditation program
ANAB AC-3279
Service Location
On-site available

3 Range Rows

Range

Up to 300 mm

CMC / Expanded Uncertainty

0.015 mm

Range

(>300 to 600) mm

CMC / Expanded Uncertainty

0.016 mm

Range

(>600 to 1 000) mm

CMC / Expanded Uncertainty

0.02 mm

Evidence DetailsShow
Source Row 1
Up to 300 mm / 0.015 mm
Method
SK-WI-011 by comparison with gage Blocks
Source Group
Height Gauge
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>300 to 600) mm / 0.016 mm
Method
SK-WI-011 by comparison with gage Blocks
Source Group
Height Gauge
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>600 to 1 000) mm / 0.02 mm
Method
SK-WI-011 by comparison with gage Blocks
Source Group
Height Gauge
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Height Gauge Calibration FAQ

Is height gauge calibration accredited?+

Accreditation may apply under ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a height gauge quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.

Need Calibration?

Ready to calibrate Height Gauge?

Request Quotation