SK Calibration Laboratory

Traceable DC electrical calibration support for laboratory and maintenance applications.

Audit-ready
Traceable
Certificate support

Supported Instruments

Electrical instruments supported

Instrument families commonly submitted for electrical calibration and related measurement services.

D

DC Voltage

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

D

DC Current

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

p

pH Meter Indicator - DC Voltage

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

D

Digital Indicators / Digital Controllers / Voltage Meters

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

D

Digital Indicators / Digital Controllers / Current Meters

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

E

Electrical Measurement of Voltage Sources

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

E

Electrical Measurement of Current Sources

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

Capability Summary

Electrical calibration capability summary

Accreditation

TISI 0261 covers the listed Temperature Indicator electrical-simulation rows. ANAB AC-3279 applies only to the DC electrical quantities specifically included in the current official accredited scope.

Measurement capability

ANAB AC-3279 electrical capability is limited to supported DC voltage and DC current quantities and depends on range, equipment type and required uncertainty.

Traceability

Calibration results are supported by traceable reference standards, controlled procedures and certificate review to support maintenance, QA and audit documentation.

Certificate

Calibration certificates are provided after completion of service to support quality systems, maintenance records and customer audit requirements.

Accredited Scope

Accredited Calibration Capability

Verified ranges and expanded measurement uncertainty from the applicable accredited scope.

Program

TISI 0261

5 verified evidence rows

Official SectionElectrical / PermanentShow 5 Evidence Rows

Parameter / Equipment

Temperature Indicator — Resistance thermometer

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

1 Range Rows

Range

-190 °C to 500 °C

CMC / Expanded Uncertainty

0.11 °C

Evidence DetailsShow
Source Row 1
-190 °C to 500 °C / 0.11 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
14
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Parameter / Equipment

Temperature Indicator — Thermocouple

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

4 Range Rows

Range

Type T: -100 °C to 400 °C

CMC / Expanded Uncertainty

0.80 °C

Range

Type K: -100 °C to 1 200 °C

CMC / Expanded Uncertainty

0.43 °C

Range

Type E: -80 °C to 780 °C

CMC / Expanded Uncertainty

0.49 °C

Range

Type J: -90 °C to 850 °C

CMC / Expanded Uncertainty

0.55 °C

Evidence DetailsShow
Source Row 1
Type T: -100 °C to 400 °C / 0.80 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
14
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
Type K: -100 °C to 1 200 °C / 0.43 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
14
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
Type E: -80 °C to 780 °C / 0.49 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
14
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
Type J: -90 °C to 850 °C / 0.55 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
14
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Program

TISI 0261 — Site

5 verified evidence rows

Official SectionElectrical / SiteShow 5 Evidence Rows

Parameter / Equipment

Temperature Indicator — Resistance thermometer

Type / Subtype
General
Accreditation program
TISI 0261 — Site
Service Location
TISI 0261 — Site

1 Range Rows

Range

-190 °C to 500 °C

CMC / Expanded Uncertainty

0.11 °C

Evidence DetailsShow
Source Row 1
-190 °C to 500 °C / 0.11 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
24
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment

Parameter / Equipment

Temperature Indicator — Thermocouple

Type / Subtype
General
Accreditation program
TISI 0261 — Site
Service Location
TISI 0261 — Site

4 Range Rows

Range

Type T: -100 °C to 400 °C

CMC / Expanded Uncertainty

0.80 °C

Range

Type K: -100 °C to 1 200 °C

CMC / Expanded Uncertainty

0.43 °C

Range

Type E: -80 °C to 780 °C

CMC / Expanded Uncertainty

0.49 °C

Range

Type J: -90 °C to 850 °C

CMC / Expanded Uncertainty

0.55 °C

Evidence DetailsShow
Source Row 1
Type T: -100 °C to 400 °C / 0.80 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
24
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 2
Type K: -100 °C to 1 200 °C / 0.43 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
24
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 3
Type E: -80 °C to 780 °C / 0.49 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
24
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 4
Type J: -90 °C to 850 °C / 0.55 °C
Method
Direct measurement with Electrical simulator
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
24
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment

Program

ANAB AC-3279

24 verified evidence rows

Official SectionElectrical – DC/Low FrequencyShow 24 Evidence Rows

Parameter / Equipment

pH Meter Indicator - DC Voltage

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

1 Range Rows

Range

(-414.12 to 414.12) mV

CMC / Expanded Uncertainty

0.17 mV

Evidence DetailsShow
Source Row 1
(-414.12 to 414.12) mV / 0.17 mV
Method
SK-WI-02 by comparison with Multifunction Calibrator
Source Group
pH Meter Indicator - DC Voltage
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

DC Voltage – Digital Indicators / Digital Controllers / Voltage Meters

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

5 Range Rows

Range

(-0.15 to 0.15) V

CMC / Expanded Uncertainty

0.001 V

Range

(>0.15 to 1.5) V

CMC / Expanded Uncertainty

0.001 2 V

Range

(>1.5 to 5) V

CMC / Expanded Uncertainty

0.002 V

Range

(>5 to 10) V

CMC / Expanded Uncertainty

0.003 V

Range

(>10 to 15) V

CMC / Expanded Uncertainty

0.003 7 V

Evidence DetailsShow
Source Row 1
(-0.15 to 0.15) V / 0.001 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>0.15 to 1.5) V / 0.001 2 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>1.5 to 5) V / 0.002 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>5 to 10) V / 0.003 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>10 to 15) V / 0.003 7 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

DC Current – Digital Indicators / Digital Controllers / Current Meters

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

5 Range Rows

Range

Up to 4 mA

CMC / Expanded Uncertainty

0.003 mA

Range

(>4 to 8) mA

CMC / Expanded Uncertainty

0.003 5 mA

Range

(>8 to 12) mA

CMC / Expanded Uncertainty

0.004 mA

Range

(>12 to 16) mA

CMC / Expanded Uncertainty

0.004 5 mA

Range

(>16 to 20) mA

CMC / Expanded Uncertainty

0.005 2 mA

Evidence DetailsShow
Source Row 1
Up to 4 mA / 0.003 mA
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Current – Digital Indicators/Digital Controllers/Current Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>4 to 8) mA / 0.003 5 mA
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Current – Digital Indicators/Digital Controllers/Current Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>8 to 12) mA / 0.004 mA
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Current – Digital Indicators/Digital Controllers/Current Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>12 to 16) mA / 0.004 5 mA
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Current – Digital Indicators/Digital Controllers/Current Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>16 to 20) mA / 0.005 2 mA
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Current – Digital Indicators/Digital Controllers/Current Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

DC Voltage – Electrical Measurement of Voltage Sources

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

8 Range Rows

Range

(-0.3 to 0.3) V

CMC / Expanded Uncertainty

0.001 9 V

Range

(>0.3 to 2) V

CMC / Expanded Uncertainty

0.002 2 V

Range

(>2 to 4) V

CMC / Expanded Uncertainty

0.002 6 V

Range

(>4 to 6) V

CMC / Expanded Uncertainty

0.003 V

Range

(>6 to 8) V

CMC / Expanded Uncertainty

0.003 2 V

Range

(>8 to 10) V

CMC / Expanded Uncertainty

0.003 6 V

Range

(>10 to 20) V

CMC / Expanded Uncertainty

0.005 3 V

Range

(>20 to 30) V

CMC / Expanded Uncertainty

0.007 1 V

Evidence DetailsShow
Source Row 1
(-0.3 to 0.3) V / 0.001 9 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>0.3 to 2) V / 0.002 2 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>2 to 4) V / 0.002 6 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>4 to 6) V / 0.003 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>6 to 8) V / 0.003 2 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 6
(>8 to 10) V / 0.003 6 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 7
(>10 to 20) V / 0.005 3 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 8
(>20 to 30) V / 0.007 1 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

DC Current – Electrical Measurement of Current Sources

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

5 Range Rows

Range

Up to 4 mA

CMC / Expanded Uncertainty

0.003 4 mA

Range

(>4 to 8) mA

CMC / Expanded Uncertainty

0.004 mA

Range

(>8 to 12) mA

CMC / Expanded Uncertainty

0.004 5 mA

Range

(>12 to 16) mA

CMC / Expanded Uncertainty

0.005 2 mA

Range

(>16 to 20) mA

CMC / Expanded Uncertainty

0.005 8 mA

Evidence DetailsShow
Source Row 1
Up to 4 mA / 0.003 4 mA
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Current – Electrical Measurement of Current Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>4 to 8) mA / 0.004 mA
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Current – Electrical Measurement of Current Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>8 to 12) mA / 0.004 5 mA
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Current – Electrical Measurement of Current Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>12 to 16) mA / 0.005 2 mA
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Current – Electrical Measurement of Current Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>16 to 20) mA / 0.005 8 mA
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Current – Electrical Measurement of Current Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Calibration Process

From quotation request to delivery

01

Request

02

Quotation

03

Receive Instrument

04

Calibration

05

Quality Review

06

Certificate

07

Delivery

FAQ

Calibration Questions

Which electrical instruments can SK calibrate?+

Typical instruments include DC Voltage, DC Current, pH Meter Indicator - DC Voltage, Digital Indicators / Digital Controllers / Voltage Meters, Digital Indicators / Digital Controllers / Current Meters, Electrical Measurement of Voltage Sources and other related instruments, depending on range, method and applicable scope.

Is electrical calibration accredited?+

TISI 0261 covers the listed Temperature Indicator electrical-simulation rows. ANAB AC-3279 applies only to the DC electrical quantities specifically included in the current official accredited scope.

Where can I check the exact measurement range and CMC?+

Exact ranges, calibration points and CMC values should be confirmed against the latest official accredited scope documents and reviewed against the specific instrument details.

What information is required for a quotation?+

Please provide the instrument type, brand, model, measurement range, required calibration points, quantity, service location and required completion date.

Official Accreditation

Verified governing documents

These official accreditation documents define the verified calibration capability for this service.

Status

Active

Accreditation Programs

TISI 0261

TISI 0261

Actions

ANAB AC-3279

ANAB AC-3279

Actions

Ready to calibrate?

Request a electrical quotation

Send us your instrument information and required schedule. Our team will review the applicable capability and prepare a quotation.

Request Quotation