S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Capability Detail

DC Voltage Calibration

Electrical calibration limited to specified ANAB AC-3279 DC electrical quantities.

Request Quotation

SK Calibration Laboratory

Electrical Calibration / DC Voltage Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

This service is discoverable from the registry, but no exact verified accredited range row is assigned to this capability page.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
14
Service Location Summary
On-site available
Accreditation Programs
ANAB AC-3279

Capability overview

DC Voltage calibration overview

DC Voltage Calibration support is built from SK's existing Electrical capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
electrical
Accreditation
ANAB AC-3279
Range mapping
parameter-filtered
Range summary
See accredited capability table on this page.
Method summary
Accredited electrical calibration procedure for DC voltage and DC current quantities.

Accredited Scope

Verified range evidence for this capability

Only verified source rows associated with this selected capability mapping are shown. Instrument-family applicability must be confirmed before claiming accreditation.

Program

ANAB AC-3279

14 verified evidence rows

Official SectionElectrical – DC/Low FrequencyShow 14 Evidence Rows

Parameter / Equipment

pH Meter Indicator - DC Voltage

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

1 Range Rows

Range

(-414.12 to 414.12) mV

CMC / Expanded Uncertainty

0.17 mV

Evidence DetailsShow
Source Row 1
(-414.12 to 414.12) mV / 0.17 mV
Method
SK-WI-02 by comparison with Multifunction Calibrator
Source Group
pH Meter Indicator - DC Voltage
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

DC Voltage – Digital Indicators / Digital Controllers / Voltage Meters

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

5 Range Rows

Range

(-0.15 to 0.15) V

CMC / Expanded Uncertainty

0.001 V

Range

(>0.15 to 1.5) V

CMC / Expanded Uncertainty

0.001 2 V

Range

(>1.5 to 5) V

CMC / Expanded Uncertainty

0.002 V

Range

(>5 to 10) V

CMC / Expanded Uncertainty

0.003 V

Range

(>10 to 15) V

CMC / Expanded Uncertainty

0.003 7 V

Evidence DetailsShow
Source Row 1
(-0.15 to 0.15) V / 0.001 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>0.15 to 1.5) V / 0.001 2 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>1.5 to 5) V / 0.002 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>5 to 10) V / 0.003 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>10 to 15) V / 0.003 7 V
Method
SK-WI-023 by comparison with Multifunction Calibrator
Source Group
DC Voltage – Digital Indicators/Digital Controllers/Voltage Meters
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
2
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

DC Voltage – Electrical Measurement of Voltage Sources

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

8 Range Rows

Range

(-0.3 to 0.3) V

CMC / Expanded Uncertainty

0.001 9 V

Range

(>0.3 to 2) V

CMC / Expanded Uncertainty

0.002 2 V

Range

(>2 to 4) V

CMC / Expanded Uncertainty

0.002 6 V

Range

(>4 to 6) V

CMC / Expanded Uncertainty

0.003 V

Range

(>6 to 8) V

CMC / Expanded Uncertainty

0.003 2 V

Range

(>8 to 10) V

CMC / Expanded Uncertainty

0.003 6 V

Range

(>10 to 20) V

CMC / Expanded Uncertainty

0.005 3 V

Range

(>20 to 30) V

CMC / Expanded Uncertainty

0.007 1 V

Evidence DetailsShow
Source Row 1
(-0.3 to 0.3) V / 0.001 9 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>0.3 to 2) V / 0.002 2 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>2 to 4) V / 0.002 6 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>4 to 6) V / 0.003 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>6 to 8) V / 0.003 2 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 6
(>8 to 10) V / 0.003 6 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 7
(>10 to 20) V / 0.005 3 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 8
(>20 to 30) V / 0.007 1 V
Method
SK-WI-024 by measurement with Multimeter
Source Group
DC Voltage – Electrical Measurement of Voltage Sources
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
3
Medium / Condition
Service Location
On-site available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

DC Voltage Calibration FAQ

Is dc voltage calibration accredited?+

Accreditation may apply under ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a dc voltage quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.