S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Capability Detail

Magnetic Flowmeter Calibration

Flow calibration for liquid flowmeter technologies already represented in current SK scope data.

ANAB AC-3279
Request Quotation

SK Calibration Laboratory

Flow Calibration / Magnetic Flowmeter Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

Rows below are exact verified accredited rows associated with this capability. Values are displayed unchanged from runtime evidence.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
10
Service Location Summary
Mobile, Permanent
Accreditation Programs
ANAB AC-3279

Capability overview

Magnetic Flowmeter calibration overview

Magnetic Flowmeter Calibration support is built from SK's existing Flow capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
flow
Accreditation
TISI 0261 / ANAB AC-3279
Range mapping
exact-range-match
Range summary
See accredited capability table on this page.
Method summary
Accredited flow calibration procedure for supported liquid flowmeter technologies.

Accredited Scope

Verified range evidence for this capability

Only exact verified source rows associated with this selected capability are shown. Official values are preserved without conversion, merging or source-group collapse.

Program

ANAB AC-3279

10 verified evidence rows

Official SectionMass and Mass RelatedShow 10 Evidence Rows

Parameter / Equipment

Volume Liquid Flow Rate – Flow Meters

Type / Subtype
Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Accreditation program
ANAB AC-3279
Service Location
Mobile Laboratory

5 Range Rows

Range

(100 to 15 000) l/h

CMC / Expanded Uncertainty

0.15 % of reading

Range

(1 000 to 40 000) l/h

CMC / Expanded Uncertainty

0.15 % of reading

Range

(15 000 to 120 000) l/h

CMC / Expanded Uncertainty

0.13 % of reading

Range

(1 to 300) m³/h

CMC / Expanded Uncertainty

0.15 % of reading

Range

(50 to 300) m³/h

CMC / Expanded Uncertainty

0.15 % of reading

Evidence DetailsShow
Source Row 1
(100 to 15 000) l/h / 0.15 % of reading
Method
SK-WI-018, SK-WI-019 with reference flow meters (Mobile Laboratory); Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Mobile Laboratory
Reference Equipment
reference flow meters
Source Row 2
(1 000 to 40 000) l/h / 0.15 % of reading
Method
SK-WI-018, SK-WI-019 with reference flow meters (Mobile Laboratory); Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Mobile Laboratory
Reference Equipment
reference flow meters
Source Row 3
(15 000 to 120 000) l/h / 0.13 % of reading
Method
SK-WI-018, SK-WI-019 with reference flow meters (Mobile Laboratory); Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Mobile Laboratory
Reference Equipment
reference flow meters
Source Row 4
(1 to 300) m³/h / 0.15 % of reading
Method
SK-WI-018, SK-WI-019 with reference flow meters (Mobile Laboratory); Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Mobile Laboratory
Reference Equipment
reference flow meters
Source Row 5
(50 to 300) m³/h / 0.15 % of reading
Method
SK-WI-018, SK-WI-019 with reference flow meters (Mobile Laboratory); Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Mobile Laboratory
Reference Equipment
reference flow meters

Parameter / Equipment

Volume Liquid Flow Rate – Flow Meters

Type / Subtype
Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Accreditation program
ANAB AC-3279
Service Location

5 Range Rows

Range

(100 to 15 000) l/h

CMC / Expanded Uncertainty

0.13 % of reading

Range

(1 000 to 40 000) l/h

CMC / Expanded Uncertainty

0.13 % of reading

Range

(15 000 to 120 000) l/h

CMC / Expanded Uncertainty

0.13 % of reading

Range

(1 to 300) m³/h

CMC / Expanded Uncertainty

0.12 % of reading

Range

(50 to 300) m³/h

CMC / Expanded Uncertainty

0.15 % of reading

Evidence DetailsShow
Source Row 1
(100 to 15 000) l/h / 0.13 % of reading
Method
SK-WI-019 with reference flow meter; Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Reference Equipment
reference flow meter
Source Row 2
(1 000 to 40 000) l/h / 0.13 % of reading
Method
SK-WI-019 with reference flow meter; Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Reference Equipment
reference flow meter
Source Row 3
(15 000 to 120 000) l/h / 0.13 % of reading
Method
SK-WI-019 with reference flow meter; Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Reference Equipment
reference flow meter
Source Row 4
(1 to 300) m³/h / 0.12 % of reading
Method
SK-WI-019 with reference flow meter; Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Reference Equipment
reference flow meter
Source Row 5
(50 to 300) m³/h / 0.15 % of reading
Method
SK-WI-019 with reference flow meter; Media: Water; Water Temperature: (15 to 40) °C
Source Group
Volume Liquid Flow Rate – Flow Meters (Ultrasonic Flowmeter, Variable Area Flowmeter, Coriolis Flowmeter, Magnetic Flow meter)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Water / (15 to 40) °C
Service Location
Reference Equipment
reference flow meter

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Magnetic Flowmeter Calibration FAQ

Is magnetic flowmeter calibration accredited?+

Accreditation may apply under TISI 0261 / ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a magnetic flowmeter quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.

Need Calibration?

Ready to calibrate Magnetic Flowmeter?

Request Quotation