S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Scope Detail

Mass & Balance Calibration

บริการสอบเทียบเครื่องชั่งและตุ้มน้ำหนักมาตรฐานสำหรับห้องปฏิบัติการ งานผลิต คลังสินค้า และงานควบคุมคุณภาพ

TISI 0261ANAB AC-3279
Request Quotation

SK Calibration Laboratory

Traceable weighing and mass calibration support for laboratories and industrial quality systems.

Audit-ready
Traceable
Certificate support

Supported Instruments

Mass & Balance instruments supported

Instrument families commonly submitted for mass & balance calibration and related measurement services.

A

Analytical Balance

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

P

Precision Balance

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

T

Top-loading Balance

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

P

Platform Scale

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

I

Industrial Scale

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

S

Standard Weight

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

M

Mass Set

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

M

Moisture Analyzer (Mass)

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

H

Hydrometer Specific Gravity

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

Capability Summary

Mass & Balance calibration capability summary

Accreditation

TISI 0261 and ANAB AC-3279 accreditation applies where the instrument family, range and method are included in the current official accredited scope.

Measurement capability

Capability is summarized at weighing-instrument and mass-standard family level and depends on capacity, resolution, accuracy class and service method.

Traceability

Calibration results are supported by traceable reference standards, controlled procedures and certificate review to support maintenance, QA and audit documentation.

Certificate

Calibration certificates are provided after completion of service to support quality systems, maintenance records and customer audit requirements.

Accredited Scope

Accredited Calibration Capability

Verified ranges and expanded measurement uncertainty from the applicable accredited scope.

Program

TISI 0261

60 verified evidence rows

Official SectionMass / PermanentShow 60 Evidence Rows

Parameter / Equipment

Electronic balance

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

16 Range Rows

Range

20 mg to 20 g

CMC / Expanded Uncertainty

90 µg

Range

>20 g to 50 g

CMC / Expanded Uncertainty

0.12 mg

Range

>50 g to 100 g

CMC / Expanded Uncertainty

0.18 mg

Range

>100 g to 200 g

CMC / Expanded Uncertainty

0.30 mg

Range

>200 g to 300 g

CMC / Expanded Uncertainty

0.43 mg

Range

>300 g to 400 g

CMC / Expanded Uncertainty

0.97 mg

Range

>400 g to 600 g

CMC / Expanded Uncertainty

1.6 mg

Range

>600 g to 2 000 g

CMC / Expanded Uncertainty

9.1 mg

Range

>2 000 g to 5 000 g

CMC / Expanded Uncertainty

14 mg

Range

>5 000 g to 6 000 g

CMC / Expanded Uncertainty

23 mg

Range

>6 000 g to 8 000 g

CMC / Expanded Uncertainty

85 mg

Range

>8 kg to 15 kg

CMC / Expanded Uncertainty

0.82 g

Range

>15 kg to 30 kg

CMC / Expanded Uncertainty

1.7 g

Range

>30 kg to 60 kg

CMC / Expanded Uncertainty

4.2 g

Range

>60 kg to 200 kg

CMC / Expanded Uncertainty

8.8 g

Range

>200 kg to 500 kg

CMC / Expanded Uncertainty

12 g

Evidence DetailsShow
Source Row 1
20 mg to 20 g / 90 µg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
>20 g to 50 g / 0.12 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
>50 g to 100 g / 0.18 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
>100 g to 200 g / 0.30 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 5
>200 g to 300 g / 0.43 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 6
>300 g to 400 g / 0.97 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 7
>400 g to 600 g / 1.6 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 8
>600 g to 2 000 g / 9.1 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 9
>2 000 g to 5 000 g / 14 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 10
>5 000 g to 6 000 g / 23 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 11
>6 000 g to 8 000 g / 85 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 12
>8 kg to 15 kg / 0.82 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 13
>15 kg to 30 kg / 1.7 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 14
>30 kg to 60 kg / 4.2 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 15
>60 kg to 200 kg / 8.8 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 16
>200 kg to 500 kg / 12 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
9
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Parameter / Equipment

Mechanical balance

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

5 Range Rows

Range

1 g to 1 000 g

CMC / Expanded Uncertainty

2.9 g

Range

>1 kg to 2 kg

CMC / Expanded Uncertainty

5.8 g

Range

>2 kg to 7 kg

CMC / Expanded Uncertainty

12 g

Range

>7 kg to 300 kg

CMC / Expanded Uncertainty

58 g

Range

>300 kg to 500 kg

CMC / Expanded Uncertainty

59 g

Evidence DetailsShow
Source Row 1
1 g to 1 000 g / 2.9 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
>1 kg to 2 kg / 5.8 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
>2 kg to 7 kg / 12 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
>7 kg to 300 kg / 58 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 5
>300 kg to 500 kg / 59 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Parameter / Equipment

Conventional mass — Class F1

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

9 Range Rows

Range

10 mg

CMC / Expanded Uncertainty

8.0 µg

Range

20 mg

CMC / Expanded Uncertainty

0.010 mg

Range

50 mg

CMC / Expanded Uncertainty

0.012 mg

Range

100 mg

CMC / Expanded Uncertainty

0.016 mg

Range

200 mg

CMC / Expanded Uncertainty

0.020 mg

Range

500 mg

CMC / Expanded Uncertainty

0.025 mg

Range

1 g

CMC / Expanded Uncertainty

0.030 mg

Range

2 g

CMC / Expanded Uncertainty

0.040 mg

Range

5 g

CMC / Expanded Uncertainty

0.050 mg

Evidence DetailsShow
Source Row 1
10 mg / 8.0 µg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
20 mg / 0.010 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
50 mg / 0.012 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
100 mg / 0.016 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 5
200 mg / 0.020 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 6
500 mg / 0.025 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 7
1 g / 0.030 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 8
2 g / 0.040 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 9
5 g / 0.050 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
10
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Parameter / Equipment

Conventional mass — Class F1

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

11 Range Rows

Range

10 g

CMC / Expanded Uncertainty

0.060 mg

Range

20 g

CMC / Expanded Uncertainty

0.080 mg

Range

50 g

CMC / Expanded Uncertainty

0.10 mg

Range

100 g

CMC / Expanded Uncertainty

0.16 mg

Range

200 g

CMC / Expanded Uncertainty

0.30 mg

Range

500 g

CMC / Expanded Uncertainty

0.80 mg

Range

1 kg

CMC / Expanded Uncertainty

1.6 mg

Range

2 kg

CMC / Expanded Uncertainty

3.0 mg

Range

5 kg

CMC / Expanded Uncertainty

8.0 mg

Range

10 kg

CMC / Expanded Uncertainty

16 mg

Range

20 kg

CMC / Expanded Uncertainty

30 mg

Evidence DetailsShow
Source Row 1
10 g / 0.060 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
20 g / 0.080 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
50 g / 0.10 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
100 g / 0.16 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 5
200 g / 0.30 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 6
500 g / 0.80 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 7
1 kg / 1.6 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 8
2 kg / 3.0 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 9
5 kg / 8.0 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 10
10 kg / 16 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 11
20 kg / 30 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
11
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Parameter / Equipment

Conventional mass

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

19 Range Rows

Range

10 mg to 20 mg

CMC / Expanded Uncertainty

0.010 mg

Range

>20 mg to 50 mg

CMC / Expanded Uncertainty

0.012 mg

Range

>50 mg to 100 mg

CMC / Expanded Uncertainty

0.016 mg

Range

>100 mg to 200 mg

CMC / Expanded Uncertainty

0.020 mg

Range

>200 mg to 500 mg

CMC / Expanded Uncertainty

0.025 mg

Range

>500 mg to 1 g

CMC / Expanded Uncertainty

0.030 mg

Range

>1 g to 2 g

CMC / Expanded Uncertainty

0.040 mg

Range

>2 g to 5 g

CMC / Expanded Uncertainty

0.050 mg

Range

>5 g to 10 g

CMC / Expanded Uncertainty

0.060 mg

Range

>10 g to 20 g

CMC / Expanded Uncertainty

0.080 mg

Range

>20 g to 50 g

CMC / Expanded Uncertainty

0.10 mg

Range

>50 g to 100 g

CMC / Expanded Uncertainty

0.16 mg

Range

>100 g to 200 g

CMC / Expanded Uncertainty

0.30 mg

Range

>200 g to 500 g

CMC / Expanded Uncertainty

0.80 mg

Range

>500 g to 1 kg

CMC / Expanded Uncertainty

1.6 mg

Range

>1 kg to 2 kg

CMC / Expanded Uncertainty

3.0 mg

Range

>2 kg to 5 kg

CMC / Expanded Uncertainty

25 mg

Range

>5 kg to 10 kg

CMC / Expanded Uncertainty

0.16 g

Range

>10 kg to 20 kg

CMC / Expanded Uncertainty

0.30 g

Evidence DetailsShow
Source Row 1
10 mg to 20 mg / 0.010 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
>20 mg to 50 mg / 0.012 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
>50 mg to 100 mg / 0.016 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
>100 mg to 200 mg / 0.020 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 5
>200 mg to 500 mg / 0.025 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 6
>500 mg to 1 g / 0.030 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 7
>1 g to 2 g / 0.040 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 8
>2 g to 5 g / 0.050 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 9
>5 g to 10 g / 0.060 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 10
>10 g to 20 g / 0.080 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 11
>20 g to 50 g / 0.10 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 12
>50 g to 100 g / 0.16 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 13
>100 g to 200 g / 0.30 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 14
>200 g to 500 g / 0.80 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 15
>500 g to 1 kg / 1.6 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 16
>1 kg to 2 kg / 3.0 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 17
>2 kg to 5 kg / 25 mg
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 18
>5 kg to 10 kg / 0.16 g
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 19
>10 kg to 20 kg / 0.30 g
Method
Based on OIML R 111-1:2004
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
12
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Program

TISI 0261 — Site

21 verified evidence rows

Official SectionMass / SiteShow 21 Evidence Rows

Parameter / Equipment

Electronic balance

Type / Subtype
General
Accreditation program
TISI 0261 — Site
Service Location
TISI 0261 — Site

16 Range Rows

Range

20 mg to 20 g

CMC / Expanded Uncertainty

90 µg

Range

>20 g to 50 g

CMC / Expanded Uncertainty

0.12 mg

Range

>50 g to 100 g

CMC / Expanded Uncertainty

0.18 mg

Range

>100 g to 200 g

CMC / Expanded Uncertainty

0.30 mg

Range

>200 g to 300 g

CMC / Expanded Uncertainty

0.43 mg

Range

>300 g to 400 g

CMC / Expanded Uncertainty

0.97 mg

Range

>400 g to 600 g

CMC / Expanded Uncertainty

1.6 mg

Range

>600 g to 2 000 g

CMC / Expanded Uncertainty

9.1 mg

Range

>2 000 g to 5 000 g

CMC / Expanded Uncertainty

14 mg

Range

>5 000 g to 6 000 g

CMC / Expanded Uncertainty

23 mg

Range

>6 000 g to 8 000 g

CMC / Expanded Uncertainty

85 mg

Range

>8 kg to 15 kg

CMC / Expanded Uncertainty

0.82 g

Range

>15 kg to 30 kg

CMC / Expanded Uncertainty

1.7 g

Range

>30 kg to 60 kg

CMC / Expanded Uncertainty

4.2 g

Range

>60 kg to 200 kg

CMC / Expanded Uncertainty

8.8 g

Range

>200 kg to 500 kg

CMC / Expanded Uncertainty

12 g

Evidence DetailsShow
Source Row 1
20 mg to 20 g / 90 µg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 2
>20 g to 50 g / 0.12 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 3
>50 g to 100 g / 0.18 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 4
>100 g to 200 g / 0.30 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 5
>200 g to 300 g / 0.43 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 6
>300 g to 400 g / 0.97 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 7
>400 g to 600 g / 1.6 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 8
>600 g to 2 000 g / 9.1 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 9
>2 000 g to 5 000 g / 14 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 10
>5 000 g to 6 000 g / 23 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 11
>6 000 g to 8 000 g / 85 mg
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 12
>8 kg to 15 kg / 0.82 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 13
>15 kg to 30 kg / 1.7 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 14
>30 kg to 60 kg / 4.2 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 15
>60 kg to 200 kg / 8.8 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 16
>200 kg to 500 kg / 12 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
21
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment

Parameter / Equipment

Mechanical balance

Type / Subtype
General
Accreditation program
TISI 0261 — Site
Service Location
TISI 0261 — Site

5 Range Rows

Range

1 g to 1 000 g

CMC / Expanded Uncertainty

2.9 g

Range

>1 kg to 2 kg

CMC / Expanded Uncertainty

5.8 g

Range

>2 kg to 7 kg

CMC / Expanded Uncertainty

12 g

Range

>7 kg to 300 kg

CMC / Expanded Uncertainty

58 g

Range

>300 kg to 500 kg

CMC / Expanded Uncertainty

59 g

Evidence DetailsShow
Source Row 1
1 g to 1 000 g / 2.9 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
22
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 2
>1 kg to 2 kg / 5.8 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
22
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 3
>2 kg to 7 kg / 12 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
22
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 4
>7 kg to 300 kg / 58 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
22
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 5
>300 kg to 500 kg / 59 g
Method
Based on UKAS LAB 14:2022
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
22
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment

Program

ANAB AC-3279

33 verified evidence rows

Official SectionMass and Mass RelatedShow 33 Evidence Rows

Parameter / Equipment

Balance/Scale

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

20 Range Rows

Range

(1 to 20) mg

CMC / Expanded Uncertainty

0.007 4 mg

Range

(>20 to 50) mg

CMC / Expanded Uncertainty

0.008 7 mg

Range

(>50 to 100) mg

CMC / Expanded Uncertainty

0.011 mg

Range

(>100 to 200) mg

CMC / Expanded Uncertainty

0.012 mg

Range

(>200 to 500) mg

CMC / Expanded Uncertainty

0.016 mg

Range

(>0.5 to 1) g

CMC / Expanded Uncertainty

0.019 mg

Range

(>1 to 2) g

CMC / Expanded Uncertainty

0.023 mg

Range

(>2 to 5) g

CMC / Expanded Uncertainty

0.029 mg

Range

(>5 to 10) g

CMC / Expanded Uncertainty

0.036 mg

Range

(>10 to 20) g

CMC / Expanded Uncertainty

0.045 mg

Range

(>20 to 50) g

CMC / Expanded Uncertainty

0.055 mg

Range

(>50 to 100) g

CMC / Expanded Uncertainty

0.09 mg

Range

(>100 to 220) g

CMC / Expanded Uncertainty

0.23 mg

Range

(>220 to 320) g

CMC / Expanded Uncertainty

0.33 mg

Range

(>320 to 500) g

CMC / Expanded Uncertainty

0.46 mg

Range

(>500 to 1 000) g

CMC / Expanded Uncertainty

0.90 mg

Range

(>1 000 to 2 000) g

CMC / Expanded Uncertainty

1.8 mg

Range

(>2 000 to 3 000) g

CMC / Expanded Uncertainty

2.9 mg

Range

(>3 000 to 5 000) g

CMC / Expanded Uncertainty

4.6 mg

Range

(>5 000 to 6 000) g

CMC / Expanded Uncertainty

5.5 mg

Evidence DetailsShow
Source Row 1
(1 to 20) mg / 0.007 4 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>20 to 50) mg / 0.008 7 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>50 to 100) mg / 0.011 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>100 to 200) mg / 0.012 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>200 to 500) mg / 0.016 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 6
(>0.5 to 1) g / 0.019 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 7
(>1 to 2) g / 0.023 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 8
(>2 to 5) g / 0.029 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 9
(>5 to 10) g / 0.036 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 10
(>10 to 20) g / 0.045 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 11
(>20 to 50) g / 0.055 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 12
(>50 to 100) g / 0.09 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 13
(>100 to 220) g / 0.23 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 14
(>220 to 320) g / 0.33 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 15
(>320 to 500) g / 0.46 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 16
(>500 to 1 000) g / 0.90 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 17
(>1 000 to 2 000) g / 1.8 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 18
(>2 000 to 3 000) g / 2.9 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 19
(>3 000 to 5 000) g / 4.6 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 20
(>5 000 to 6 000) g / 5.5 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
4
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

Balance/Scale

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

10 Range Rows

Range

(>6 to 10) kg

CMC / Expanded Uncertainty

10 mg

Range

(>10 to 20) kg

CMC / Expanded Uncertainty

21 mg

Range

(>20 to 50) kg

CMC / Expanded Uncertainty

0.99 g

Range

(>50 to 100) kg

CMC / Expanded Uncertainty

2.7 g

Range

(>100 to 200) kg

CMC / Expanded Uncertainty

4.7 g

Range

(>200 to 300) kg

CMC / Expanded Uncertainty

7.2 g

Range

(>300 to 500) kg

CMC / Expanded Uncertainty

16 g

Range

(>500 to 1 000) kg

CMC / Expanded Uncertainty

95 g

Range

(>1 000 to 2 000) kg

CMC / Expanded Uncertainty

0.11 kg

Range

(>2 000 to 3 000) kg

CMC / Expanded Uncertainty

0.12 kg

Evidence DetailsShow
Source Row 1
(>6 to 10) kg / 10 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>10 to 20) kg / 21 mg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>20 to 50) kg / 0.99 g
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>50 to 100) kg / 2.7 g
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>100 to 200) kg / 4.7 g
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 6
(>200 to 300) kg / 7.2 g
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 7
(>300 to 500) kg / 16 g
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 8
(>500 to 1 000) kg / 95 g
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 9
(>1 000 to 2 000) kg / 0.11 kg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 10
(>2 000 to 3 000) kg / 0.12 kg
Method
SK-WI-013 based on UKAS LAB 14:2019
Source Group
Balance/Scale
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

Moisture Analyzer (Balance)

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

2 Range Rows

Range

Up to 100 g

CMC / Expanded Uncertainty

0.6 mg

Range

(>100 to 200) g

CMC / Expanded Uncertainty

0.64 mg

Evidence DetailsShow
Source Row 1
Up to 100 g / 0.6 mg
Method
SK-WI-012 based on UKAS LAB 14:2019
Source Group
Moisture Analyzer (Balance)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>100 to 200) g / 0.64 mg
Method
SK-WI-012 based on UKAS LAB 14:2019
Source Group
Moisture Analyzer (Balance)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
5
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

Hydrometer Specific Gravity (Relative Density)

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location

1 Range Rows

Range

(0.6 to 2) g/cm³

CMC / Expanded Uncertainty

0.000 5 g/cm³

Evidence DetailsShow
Source Row 1
(0.6 to 2) g/cm³ / 0.000 5 g/cm³
Method
SK-WI-007 using values of Density of Solid Artifact and Electronic Balance (Cuckow’s Method)
Source Group
Hydrometer Specific Gravity (Relative Density) (~25 °C)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
~25 °C
Service Location
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Calibration Process

From quotation request to delivery

01

Request

02

Quotation

03

Receive Instrument

04

Calibration

05

Quality Review

06

Certificate

07

Delivery

FAQ

Calibration Questions

Which mass & balance instruments can SK calibrate?+

Typical instruments include Analytical Balance, Precision Balance, Top-loading Balance, Platform Scale, Industrial Scale, Standard Weight and other related instruments, depending on range, method and applicable scope.

Is mass & balance calibration accredited?+

TISI 0261 and ANAB AC-3279 accreditation applies where the instrument family, range and method are included in the current official accredited scope.

Where can I check the exact measurement range and CMC?+

Exact ranges, calibration points and CMC values should be confirmed against the latest official accredited scope documents and reviewed against the specific instrument details.

What information is required for a quotation?+

Please provide the instrument type, brand, model, measurement range, required calibration points, quantity, service location and required completion date.

Official Accreditation

Verified governing documents

These official accreditation documents define the verified calibration capability for this service.

Status

Active

Accreditation Programs

TISI 0261

TISI 0261

Actions

ANAB AC-3279

ANAB AC-3279

Actions

Ready to calibrate?

Request a mass & balance quotation

Send us your instrument information and required schedule. Our team will review the applicable capability and prepare a quotation.

Request Quotation