S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Capability Detail

Pressure Safety Valve Calibration

Pressure calibration for process, utility and level-related pressure instruments under TISI 0261 and verified ANAB AC-3279 pressure entries.

Request Quotation

SK Calibration Laboratory

Pressure Calibration / Pressure Safety Valve Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

Rows below are exact verified accredited rows associated with this capability. Values are displayed unchanged from runtime evidence.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
4
Service Location Summary
On-site available
Accreditation Programs
Confirm from official scope

Capability overview

Pressure Safety Valve calibration overview

Pressure Safety Valve Calibration support is built from SK's existing Pressure capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
pressure
Accreditation
ANAB AC-3279
Range mapping
exact-range-match
Range summary
See accredited capability table on this page.
Method summary
Verified ANAB pressure methods include SK-WI-020, SK-WI-025 and SK-WI-026 by comparison with Pressure Calibrator where applicable.

Accredited Scope

Verified range evidence for this capability

Only exact verified source rows associated with this selected capability are shown. Official values are preserved without conversion, merging or source-group collapse.

Program

ANAB AC-3279

4 verified evidence rows

Official SectionMass and Mass RelatedShow 4 Evidence Rows

Parameter / Equipment

Pressure Safety Valves

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
onsite-available

4 Range Rows

Range

Pneumatic (Air): (>0 to 200) kPa

CMC / Expanded Uncertainty

0.3 kPa

Range

Pneumatic (Air): (>200 to 2 000) kPa

CMC / Expanded Uncertainty

0.81 kPa

Range

Pneumatic (Air): (>2 000 to 7 000) kPa

CMC / Expanded Uncertainty

1.8 kPa

Range

Hydraulic (Oil): (0 to 70) MPa

CMC / Expanded Uncertainty

20 kPa

Evidence DetailsShow
Source Row 1
Pneumatic (Air): (>0 to 200) kPa / 0.3 kPa
Method
SK-WI-025 by comparison with Pressure Calibrator
Source Group
Pressure Safety Valves (Pressure release point)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 2
Pneumatic (Air): (>200 to 2 000) kPa / 0.81 kPa
Method
SK-WI-025 by comparison with Pressure Calibrator
Source Group
Pressure Safety Valves (Pressure release point)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 3
Pneumatic (Air): (>2 000 to 7 000) kPa / 1.8 kPa
Method
SK-WI-025 by comparison with Pressure Calibrator
Source Group
Pressure Safety Valves (Pressure release point)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 4
Hydraulic (Oil): (0 to 70) MPa / 20 kPa
Method
SK-WI-025 by comparison with Pressure Calibrator
Source Group
Pressure Safety Valves (Pressure release point)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
6
Medium / Condition
Service Location
onsite-available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Pressure Safety Valve Calibration FAQ

Is pressure safety valve calibration accredited?+

Accreditation may apply under ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a pressure safety valve quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.

Need Calibration?

Ready to calibrate Pressure Safety Valve?

Request Quotation