S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Capability Detail

Tachometer Calibration

Speed calibration for tachometer and rotational speed instruments represented in the ANAB scope.

Request Quotation

SK Calibration Laboratory

Speed Calibration / Tachometer Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

Rows below come from verified source rows mapped at instrument-family level. Confirm applicability to the submitted instrument before making an accreditation claim.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
10
Service Location Summary
On-site available
Accreditation Programs
Confirm from official scope

Capability overview

Tachometer calibration overview

Tachometer Calibration support is built from SK's existing Speed capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
speed
Accreditation
ANAB AC-3279
Range mapping
family-level-match
Range summary
See accredited capability table on this page.
Method summary
SK-WI-021 by comparison to a multifunction calibrator.

Accredited Scope

Verified range evidence for this capability

Only verified source rows associated with this selected capability mapping are shown. Instrument-family applicability must be confirmed before claiming accreditation.

Program

ANAB AC-3279

10 verified evidence rows

Official SectionTime and FrequencyShow 10 Evidence Rows

Parameter / Equipment

Tachometer, RPM – Rotational Speed (Non-Contact)

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
onsite-available

10 Range Rows

Range

(>6.0 to 99.99) rpm

CMC / Expanded Uncertainty

0.015 rpm

Range

(>99.99 to 180.0) rpm

CMC / Expanded Uncertainty

0.06 rpm

Range

(>180.0 to 500.0) rpm

CMC / Expanded Uncertainty

0.07 rpm

Range

(>500.0 to 999.9) rpm

CMC / Expanded Uncertainty

0.12 rpm

Range

(>999.9 to 2 000) rpm

CMC / Expanded Uncertainty

0.6 rpm

Range

(>2 000 to 5 000) rpm

CMC / Expanded Uncertainty

0.9 rpm

Range

(>5 000 to 10 000) rpm

CMC / Expanded Uncertainty

1.2 rpm

Range

(>10 000 to 20 000) rpm

CMC / Expanded Uncertainty

1.7 rpm

Range

(>20 000 to 50 000) rpm

CMC / Expanded Uncertainty

6.8 rpm

Range

(>50 000 to 99 999) rpm

CMC / Expanded Uncertainty

10 rpm

Evidence DetailsShow
Source Row 1
(>6.0 to 99.99) rpm / 0.015 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 2
(>99.99 to 180.0) rpm / 0.06 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 3
(>180.0 to 500.0) rpm / 0.07 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 4
(>500.0 to 999.9) rpm / 0.12 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 5
(>999.9 to 2 000) rpm / 0.6 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 6
(>2 000 to 5 000) rpm / 0.9 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 7
(>5 000 to 10 000) rpm / 1.2 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 8
(>10 000 to 20 000) rpm / 1.7 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 9
(>20 000 to 50 000) rpm / 6.8 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 10
(>50 000 to 99 999) rpm / 10 rpm
Method
SK-WI-021 Comparison to Multifunction calibrator
Source Group
Tachometer RPM – Rotational Speed (Non-Contact)
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Tachometer Calibration FAQ

Is tachometer calibration accredited?+

Accreditation may apply under ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a tachometer quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.

Need Calibration?

Ready to calibrate Tachometer?

Request Quotation