Liquid-in-Glass Thermometer Calibration

Temperature calibration for industrial sensors, indicators and controlled thermal equipment, with TISI shown as the primary scope.

TISI 0261ANAB AC-3279
Request Quotation

SK Calibration Laboratory

Temperature Calibration / Liquid-in-Glass Thermometer Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

Rows below are exact verified accredited rows associated with this capability. Values are displayed unchanged from runtime evidence.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
6
Service Location Summary
Permanent, Site, On-site available
Accreditation Programs
TISI 0261ANAB AC-3279

Capability overview

Liquid-in-Glass Thermometer calibration overview

Liquid-in-Glass Thermometer Calibration support is built from SK's existing Temperature capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
temperature
Accreditation
TISI 0261 / ANAB AC-3279
Range mapping
exact-range-match
Range summary
See accredited capability table on this page.
Method summary
Accredited temperature calibration procedure appropriate to the listed instrument family.

Accredited Scope

Verified range evidence for this capability

Only exact verified source rows associated with this selected capability are shown. Official values are preserved without conversion, merging or source-group collapse.

Program

TISI 0261

2 verified evidence rows

Official SectionOfficial scope evidenceShow 2 Evidence Rows

Parameter / Equipment

Liquid in glass thermometer for retort and pipe

Type / Subtype
straight; 90° back angle; 135° oblique angle
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

2 Range Rows

Range

-30 °C to 75 °C

CMC / Expanded Uncertainty

0.60 °C

Range

>75 °C to 135 °C

CMC / Expanded Uncertainty

0.33 °C

Evidence DetailsShow
Source Row 1
-30 °C to 75 °C / 0.60 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
2
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
>75 °C to 135 °C / 0.33 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
2
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Program

TISI 0261 — Site

2 verified evidence rows

Official SectionOfficial scope evidenceShow 2 Evidence Rows

Parameter / Equipment

Liquid in glass thermometer for retort and pipe

Type / Subtype
straight; 90° back angle; 135° oblique angle
Accreditation program
TISI 0261 — Site
Service Location
TISI 0261 — Site

2 Range Rows

Range

-30 °C to 75 °C

CMC / Expanded Uncertainty

0.60 °C

Range

>75 °C to 135 °C

CMC / Expanded Uncertainty

0.33 °C

Evidence DetailsShow
Source Row 1
-30 °C to 75 °C / 0.60 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
16
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 2
>75 °C to 135 °C / 0.33 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
16
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment

Program

ANAB AC-3279

2 verified evidence rows

Official SectionThermodynamicShow 2 Evidence Rows

Parameter / Equipment

Liquid in Glass Thermometers

Type / Subtype
Total Immersion
Accreditation program
ANAB AC-3279
Service Location
On-site available

1 Range Rows

Range

(-40 to 200) °C

CMC / Expanded Uncertainty

0.08 °C

Evidence DetailsShow
Source Row 1
(-40 to 200) °C / 0.08 °C
Method
SK-WI-015 by Comparison to Digital thermometer with PRT sensor
Source Group
Liquid in Glass Thermometers - Total Immersion
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
7
Medium / Condition
Service Location
On-site available
Reference Equipment

Parameter / Equipment

Liquid in Glass Thermometers

Type / Subtype
Partial Immersion
Accreditation program
ANAB AC-3279
Service Location
On-site available

1 Range Rows

Range

(-40 to 200) °C

CMC / Expanded Uncertainty

0.08 °C

Evidence DetailsShow
Source Row 1
(-40 to 200) °C / 0.08 °C
Method
SK-WI-015 by Comparison to Digital thermometer with PRT sensor
Source Group
Liquid in Glass Thermometers - Partial Immersion
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
7
Medium / Condition
Service Location
On-site available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Liquid-in-Glass Thermometer Calibration FAQ

Is liquid-in-glass thermometer calibration accredited?+

Accreditation may apply under TISI 0261 / ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a liquid-in-glass thermometer quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.

Need Calibration?

Ready to calibrate Liquid-in-Glass Thermometer?

Request Quotation