Temperature Indicator with Sensor Calibration

Temperature calibration for industrial sensors, indicators and controlled thermal equipment, with TISI shown as the primary scope.

TISI 0261
Request Quotation

SK Calibration Laboratory

Temperature Calibration / Temperature Indicator with Sensor Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

Rows below are exact verified accredited rows associated with this capability. Values are displayed unchanged from runtime evidence.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
21
Service Location Summary
Permanent, Site
Accreditation Programs
TISI 0261

Capability overview

Temperature Indicator with Sensor calibration overview

Temperature Indicator with Sensor Calibration support is built from SK's existing Temperature capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
temperature
Accreditation
TISI 0261
Range mapping
exact-range-match
Range summary
See accredited capability table on this page.
Method summary
Accredited temperature calibration procedure appropriate to the listed instrument family.

Accredited Scope

Verified range evidence for this capability

Only exact verified source rows associated with this selected capability are shown. Official values are preserved without conversion, merging or source-group collapse.

Program

TISI 0261

11 verified evidence rows

Official SectionOfficial scope evidenceShow 11 Evidence Rows

Parameter / Equipment

Temperature indicator with sensor

Type / Subtype
Resistance Thermometer
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

3 Range Rows

Range

-40 °C to 125 °C

CMC / Expanded Uncertainty

0.11 °C

Range

>125 °C to 200 °C

CMC / Expanded Uncertainty

0.15 °C

Range

>200 °C to 400 °C

CMC / Expanded Uncertainty

0.28 °C

Evidence DetailsShow
Source Row 1
-40 °C to 125 °C / 0.11 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
>125 °C to 200 °C / 0.15 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
>200 °C to 400 °C / 0.28 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Parameter / Equipment

Temperature indicator with sensor

Type / Subtype
Thermocouple Types J, K, E, T, N
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

8 Range Rows

Range

-40 °C to 50 °C

CMC / Expanded Uncertainty

0.26 °C

Range

>50 °C to 100 °C

CMC / Expanded Uncertainty

0.40 °C

Range

>100 °C to 150 °C

CMC / Expanded Uncertainty

0.56 °C

Range

>150 °C to 200 °C

CMC / Expanded Uncertainty

0.72 °C

Range

>200 °C to 250 °C

CMC / Expanded Uncertainty

0.92 °C

Range

>250 °C to 300 °C

CMC / Expanded Uncertainty

1.1 °C

Range

>300 °C to 350 °C

CMC / Expanded Uncertainty

1.3 °C

Range

>350 °C to 400 °C

CMC / Expanded Uncertainty

1.5 °C

Evidence DetailsShow
Source Row 1
-40 °C to 50 °C / 0.26 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
>50 °C to 100 °C / 0.40 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
>100 °C to 150 °C / 0.56 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
>150 °C to 200 °C / 0.72 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 5
>200 °C to 250 °C / 0.92 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 6
>250 °C to 300 °C / 1.1 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 7
>300 °C to 350 °C / 1.3 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 8
>350 °C to 400 °C / 1.5 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
1
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Program

TISI 0261 — Site

10 verified evidence rows

Official SectionOfficial scope evidenceShow 10 Evidence Rows

Parameter / Equipment

Temperature indicator with sensor

Type / Subtype
Resistance Thermometer
Accreditation program
TISI 0261 — Site
Service Location
TISI 0261 — Site

2 Range Rows

Range

-40 °C to 200 °C

CMC / Expanded Uncertainty

0.16 °C

Range

>200 °C to 400 °C

CMC / Expanded Uncertainty

0.28 °C

Evidence DetailsShow
Source Row 1
-40 °C to 200 °C / 0.16 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 2
>200 °C to 400 °C / 0.28 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment

Parameter / Equipment

Temperature indicator with sensor

Type / Subtype
Thermocouple Types J, K, E, T, N
Accreditation program
TISI 0261 — Site
Service Location
TISI 0261 — Site

8 Range Rows

Range

-40 °C to 50 °C

CMC / Expanded Uncertainty

0.26 °C

Range

>50 °C to 100 °C

CMC / Expanded Uncertainty

0.40 °C

Range

>100 °C to 150 °C

CMC / Expanded Uncertainty

0.56 °C

Range

>150 °C to 200 °C

CMC / Expanded Uncertainty

0.72 °C

Range

>200 °C to 250 °C

CMC / Expanded Uncertainty

0.92 °C

Range

>250 °C to 300 °C

CMC / Expanded Uncertainty

1.1 °C

Range

>300 °C to 350 °C

CMC / Expanded Uncertainty

1.3 °C

Range

>350 °C to 400 °C

CMC / Expanded Uncertainty

1.5 °C

Evidence DetailsShow
Source Row 1
-40 °C to 50 °C / 0.26 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 2
>50 °C to 100 °C / 0.40 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 3
>100 °C to 150 °C / 0.56 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 4
>150 °C to 200 °C / 0.72 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 5
>200 °C to 250 °C / 0.92 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 6
>250 °C to 300 °C / 1.1 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 7
>300 °C to 350 °C / 1.3 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment
Source Row 8
>350 °C to 400 °C / 1.5 °C
Method
Comparison with Standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
15
Medium / Condition
Service Location
TISI 0261 — Site
Reference Equipment

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Temperature Indicator with Sensor Calibration FAQ

Is temperature indicator with sensor calibration accredited?+

Accreditation may apply under TISI 0261 when the instrument, range and method are included in the current official scope.

What information is needed for a temperature indicator with sensor quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.

Need Calibration?

Ready to calibrate Temperature Indicator with Sensor?

Request Quotation