S K SALES & SERVICE
S K SALES & SERVICECO., LTD.

Capability Detail

Thermometer with Sensor / Temperature Data Logger Calibration

Temperature calibration for industrial sensors, indicators and controlled thermal equipment, with TISI shown as the primary scope.

Request Quotation

SK Calibration Laboratory

Temperature Calibration / Thermometer with Sensor / Temperature Data Logger Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

Rows below come from verified source rows mapped at instrument-family level. Confirm applicability to the submitted instrument before making an accreditation claim.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
5
Service Location Summary
On-site available
Accreditation Programs
ANAB AC-3279

Capability overview

Thermometer with Sensor / Temperature Data Logger calibration overview

Thermometer with Sensor / Temperature Data Logger Calibration support is built from SK's existing Temperature capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
temperature
Accreditation
ANAB AC-3279
Range mapping
family-level-match
Range summary
See accredited capability table on this page.
Method summary
Accredited temperature calibration procedure appropriate to the listed instrument family.

Accredited Scope

Verified range evidence for this capability

Only verified source rows associated with this selected capability mapping are shown. Instrument-family applicability must be confirmed before claiming accreditation.

Program

ANAB AC-3279

5 verified evidence rows

Official SectionThermodynamicShow 5 Evidence Rows

Parameter / Equipment

Thermometer with sensor / Temperature Data Logger

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
On-site available

5 Range Rows

Range

(-40 to 200) °C

CMC / Expanded Uncertainty

0.05 °C

Range

(>200 to 400) °C

CMC / Expanded Uncertainty

0.17 °C

Range

(>400 to 500) °C

CMC / Expanded Uncertainty

0.21 °C

Range

(>500 to 650) °C

CMC / Expanded Uncertainty

2.6 °C

Range

(>650 to 1 200) °C

CMC / Expanded Uncertainty

3.4 °C

Evidence DetailsShow
Source Row 1
(-40 to 200) °C / 0.05 °C
Method
SK-WI-016 by Comparison to Standard Thermometer
Source Group
Thermometer with sensor / Temperature Data Logger
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
7
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 2
(>200 to 400) °C / 0.17 °C
Method
SK-WI-016 by Comparison to Standard Thermometer
Source Group
Thermometer with sensor / Temperature Data Logger
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
7
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 3
(>400 to 500) °C / 0.21 °C
Method
SK-WI-016 by Comparison to Standard Thermometer
Source Group
Thermometer with sensor / Temperature Data Logger
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
7
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 4
(>500 to 650) °C / 2.6 °C
Method
SK-WI-016 by Comparison to Standard Thermometer
Source Group
Thermometer with sensor / Temperature Data Logger
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
7
Medium / Condition
Service Location
On-site available
Reference Equipment
Source Row 5
(>650 to 1 200) °C / 3.4 °C
Method
SK-WI-016 by Comparison to Standard Thermometer
Source Group
Thermometer with sensor / Temperature Data Logger
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
7
Medium / Condition
Service Location
On-site available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Thermometer with Sensor / Temperature Data Logger Calibration FAQ

Is thermometer with sensor / temperature data logger calibration accredited?+

Accreditation may apply under ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a thermometer with sensor / temperature data logger quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.

Need Calibration?

Ready to calibrate Thermometer with Sensor / Temperature Data Logger?

Request Quotation