Device Output Function Calibration

Time and frequency calibration for timing, frequency and pulse-counting instruments represented in the ANAB scope.

Request Quotation

SK Calibration Laboratory

Time & Frequency Calibration / Device Output Function Calibration

Audit-ready
Traceable
Certificate support

Decision Summary

Capability decision at a glance

This service is discoverable from the registry, but no exact verified accredited range row is assigned to this capability page.

Calibration Availability
Available in runtime evidence
Verified Evidence Count
5
Service Location Summary
On-site available
Accreditation Programs
Confirm from official scope

Capability overview

Device Output Function calibration overview

Device Output Function Calibration support is built from SK's existing Time & Frequency capability data and applicable accredited scope information.

Exact ranges, calibration points, CMC values and accreditation claims should be confirmed against the latest official scope before quotation.

Parent scope
time
Accreditation
ANAB AC-3279
Range mapping
parameter-filtered
Range summary
See accredited capability table on this page.
Method summary
SK-WI-008, SK-WI-023 and SK-WI-024 using frequency-counter, multifunction-calibrator and multimeter comparison methods.

Accredited Scope

Verified range evidence for this capability

Only verified source rows associated with this selected capability mapping are shown. Instrument-family applicability must be confirmed before claiming accreditation.

Program

ANAB AC-3279

5 verified evidence rows

Official SectionTime and FrequencyShow 5 Evidence Rows

Parameter / Equipment

Frequency – Frequency Sources / Device Output Function

Type / Subtype
General
Accreditation program
ANAB AC-3279
Service Location
onsite-available

5 Range Rows

Range

(0.1 to 5) Hz

CMC / Expanded Uncertainty

0.003 Hz

Range

(>5 to 50) Hz

CMC / Expanded Uncertainty

0.055 Hz

Range

(>50 to 500) Hz

CMC / Expanded Uncertainty

0.060 Hz

Range

(>500 to 5 000) Hz

CMC / Expanded Uncertainty

0.60 Hz

Range

(>5 000 to 50 000) Hz

CMC / Expanded Uncertainty

3.2 Hz

Evidence DetailsShow
Source Row 1
(0.1 to 5) Hz / 0.003 Hz
Method
SK-WI-024 by comparison with Multimeter
Source Group
Frequency – Sources / Frequency Device Output Function
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 2
(>5 to 50) Hz / 0.055 Hz
Method
SK-WI-024 by comparison with Multimeter
Source Group
Frequency – Sources / Frequency Device Output Function
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 3
(>50 to 500) Hz / 0.060 Hz
Method
SK-WI-024 by comparison with Multimeter
Source Group
Frequency – Sources / Frequency Device Output Function
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 4
(>500 to 5 000) Hz / 0.60 Hz
Method
SK-WI-024 by comparison with Multimeter
Source Group
Frequency – Sources / Frequency Device Output Function
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment
Source Row 5
(>5 000 to 50 000) Hz / 3.2 Hz
Method
SK-WI-024 by comparison with Multimeter
Source Group
Frequency – Sources / Frequency Device Output Function
Source Document
ANAB AC-3279 scope version 004, last updated 26 January 2026
Source Page
8
Medium / Condition
Service Location
onsite-available
Reference Equipment

On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.

Typical applications

  • Production quality control
  • Preventive maintenance
  • ISO/IEC 17025 and customer audit records
  • Incoming and periodic instrument verification

Industries

  • Manufacturing
  • Laboratory
  • Utilities
  • Process industry

Supported brands

  • Fluke
  • Mitutoyo
  • Yokogawa
  • WIKA
  • Testo
  • Customer-supplied brands

Related capabilities

Related cards are service-discovery links only; accreditation badges are withheld unless exact capability evidence supports them on the destination page.

Supporting Documents

Official References

FAQ

Device Output Function Calibration FAQ

Is device output function calibration accredited?+

Accreditation may apply under ANAB AC-3279 when the instrument, range and method are included in the current official scope.

What information is needed for a device output function quotation?+

Please provide brand, model, range, calibration points, quantity, location and required completion date.