Vernier Caliper
Typical Applications
- Production
- Laboratory
- Quality Control
Calibration Availability
Available under the accredited scope where applicable.
Scope Detail
Dimension Calibration calibration for industrial, laboratory and quality-control applications with traceable measurement results.
SK Calibration Laboratory
Traceable dimension calibration calibration support for industrial and laboratory applications.
Supported Instruments
Instrument families supported for dimension calibration calibration. Confirm the model, range and required calibration points with our team.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Available under the accredited scope where applicable.
Capability Summary
Accreditation
Accreditation status depends on the instrument type, range and entries in the latest official accredited scope.
Traceability
Calibration results use traceable reference standards, controlled procedures and certificate review.
Certificate
A calibration certificate is provided after service completion to support quality and audit records.
Accredited Scope
Verified ranges and expanded measurement uncertainty from the applicable accredited scope.
Program
12 verified evidence rows
Parameter / Equipment
3 Range Rows
Range
0 mm to 150 mm
CMC / Expanded Uncertainty
15 µm
Range
> 150 mm to 200 mm
CMC / Expanded Uncertainty
16 µm
Range
> 200 mm to 300 mm
CMC / Expanded Uncertainty
18 µm
Parameter / Equipment
1 Range Rows
Range
0 mm to 25 mm
CMC / Expanded Uncertainty
1.5 µm
Parameter / Equipment
1 Range Rows
Range
0 mm to 13 mm
CMC / Expanded Uncertainty
5.9 µm
Parameter / Equipment
2 Range Rows
Range
0 mm to 10 mm
CMC / Expanded Uncertainty
1.4 µm
Range
> 10 mm to 25 mm
CMC / Expanded Uncertainty
5.9 µm
Parameter / Equipment
1 Range Rows
Range
0 mm to 2 mm
CMC / Expanded Uncertainty
4.0 µm
Parameter / Equipment
3 Range Rows
Range
0 mm to 10 mm
CMC / Expanded Uncertainty
4.0 µm
Range
> 10 mm to 25 mm
CMC / Expanded Uncertainty
4.1 µm
Range
> 25 mm to 50 mm
CMC / Expanded Uncertainty
4.5 µm
Parameter / Equipment
1 Range Rows
Range
0 mm to 1.5 mm
CMC / Expanded Uncertainty
4.6 µm
Program
33 verified evidence rows
Parameter / Equipment
3 Range Rows
Range
Up to 300 mm
CMC / Expanded Uncertainty
0.015 mm
Range
(>300 to 600) mm
CMC / Expanded Uncertainty
0.016 mm
Range
(>600 to 1 000) mm
CMC / Expanded Uncertainty
0.02 mm
Parameter / Equipment
2 Range Rows
Range
Up to 1 000 mm
CMC / Expanded Uncertainty
0.031 mm
Range
(>1 000 to 2 000) mm
CMC / Expanded Uncertainty
0.058 mm
Parameter / Equipment
14 Range Rows
Range
Up to 1 m
CMC / Expanded Uncertainty
0.021 mm
Range
(>1 to 2) m
CMC / Expanded Uncertainty
0.031 mm
Range
(>2 to 3) m
CMC / Expanded Uncertainty
0.043 mm
Range
(>3 to 4) m
CMC / Expanded Uncertainty
0.056 mm
Range
(>4 to 5) m
CMC / Expanded Uncertainty
0.069 mm
Range
(>5 to 6) m
CMC / Expanded Uncertainty
0.082 mm
Range
(>6 to 7) m
CMC / Expanded Uncertainty
0.095 mm
Range
(>7 to 8) m
CMC / Expanded Uncertainty
0.11 mm
Range
(>8 to 9) m
CMC / Expanded Uncertainty
0.13 mm
Range
(>9 to 10) m
CMC / Expanded Uncertainty
0.14 mm
Range
(>10 to 20) m
CMC / Expanded Uncertainty
0.27 mm
Range
(>20 to 30) m
CMC / Expanded Uncertainty
0.4 mm
Range
(>30 to 40) m
CMC / Expanded Uncertainty
0.54 mm
Range
(>40 to 50) m
CMC / Expanded Uncertainty
0.67 mm
Parameter / Equipment
14 Range Rows
Range
Up to 1 m
CMC / Expanded Uncertainty
0.049 mm
Range
(>1 to 2) m
CMC / Expanded Uncertainty
0.094 mm
Range
(>2 to 3) m
CMC / Expanded Uncertainty
0.14 mm
Range
(>3 to 4) m
CMC / Expanded Uncertainty
0.19 mm
Range
(>4 to 5) m
CMC / Expanded Uncertainty
0.24 mm
Range
(>5 to 6) m
CMC / Expanded Uncertainty
0.28 mm
Range
(>6 to 7) m
CMC / Expanded Uncertainty
0.33 mm
Range
(>7 to 8) m
CMC / Expanded Uncertainty
0.37 mm
Range
(>8 to 9) m
CMC / Expanded Uncertainty
0.42 mm
Range
(>9 to 10) m
CMC / Expanded Uncertainty
0.47 mm
Range
(>10 to 20) m
CMC / Expanded Uncertainty
0.93 mm
Range
(>20 to 30) m
CMC / Expanded Uncertainty
1.4 mm
Range
(>30 to 40) m
CMC / Expanded Uncertainty
1.9 mm
Range
(>40 to 50) m
CMC / Expanded Uncertainty
2.4 mm
On-site calibration is available for this parameter. Actual on-site measurement uncertainty may be greater than the CMC shown in the accredited scope.
Calibration Process
FAQ
Review the instrument list and capability table on this page, or contact our team to confirm the model and range.
Please provide instrument type, brand, model, range, required points, quantity, service location and required completion date.
Official Accreditation
These official accreditation documents define the verified calibration capability for this service.
Status
Accreditation Programs
RELATED SERVICES
Explore related calibration capabilities commonly requested alongside this service.
Mass and balance calibration for weighing instruments and mass standards.
Torque calibration support for hand torque tools and rotational-force measurement instruments.
Temperature calibration for industrial sensors, indicators and controlled thermal equipment, with TISI shown as the primary scope.
Ready to calibrate?
Send your instrument details and required schedule. Our team will confirm the applicable capability.