S K Sale and Service Co.,Ltd.
S K Sale and Service Co.,Ltd.

Scope Detail

Humidity Calibration

Humidity calibration for monitoring, logging and controlled-environment instruments.

TISI 0261
Request Quotation

SK Calibration Laboratory

Traceable humidity calibration support for industrial and laboratory applications.

Audit-ready
Traceable
Certificate support

Supported Instruments

Humidity instruments supported

Instrument families supported for humidity calibration. Confirm the model, range and required calibration points with our team.

T

Thermo-Hygrometer

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

T

Temperature/Humidity Logger

Typical Applications

  • Production
  • Laboratory
  • Quality Control

Calibration Availability

Available under the accredited scope where applicable.

Capability Summary

Humidity calibration capability summary

Accreditation

Accreditation status depends on the instrument type, range and entries in the latest official accredited scope.

Traceability

Calibration results use traceable reference standards, controlled procedures and certificate review.

Certificate

A calibration certificate is provided after service completion to support quality and audit records.

Accredited Scope

Accredited Calibration Capability

Verified ranges and expanded measurement uncertainty from the applicable accredited scope.

Program

TISI 0261

6 verified evidence rows

Official SectionHumidity / PermanentShow 6 Evidence Rows

Parameter / Equipment

Thermo-hygrometer and Temperature/humidity logger

Type / Subtype
General
Accreditation program
TISI 0261
Service Location
TISI 0261 — Permanent

6 Range Rows

Range

Temperature: 0 °C to 35 °C

CMC / Expanded Uncertainty

0.35 °C

Range

Temperature: >35 °C to 50 °C

CMC / Expanded Uncertainty

0.47 °C

Range

Relative humidity at 25 °C: 20 % to 40 %

CMC / Expanded Uncertainty

2.1 %

Range

Relative humidity at 25 °C: >40 % to 60 %

CMC / Expanded Uncertainty

2.3 %

Range

Relative humidity at 25 °C: >60 % to 80 %

CMC / Expanded Uncertainty

2.8 %

Range

Relative humidity at 25 °C: >80 % to 90 %

CMC / Expanded Uncertainty

3.1 %

Evidence DetailsShow
Source Row 1
Temperature: 0 °C to 35 °C / 0.35 °C
Method
Comparison with Humidity standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
5
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 2
Temperature: >35 °C to 50 °C / 0.47 °C
Method
Comparison with Humidity standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
5
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 3
Relative humidity at 25 °C: 20 % to 40 % / 2.1 %
Method
Comparison with Humidity standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
5
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 4
Relative humidity at 25 °C: >40 % to 60 % / 2.3 %
Method
Comparison with Humidity standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
5
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 5
Relative humidity at 25 °C: >60 % to 80 % / 2.8 %
Method
Comparison with Humidity standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
5
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment
Source Row 6
Relative humidity at 25 °C: >80 % to 90 % / 3.1 %
Method
Comparison with Humidity standard thermometer
Source Group
Official source group
Source Document
TISI 0261 certificate 22-LB0022, Calibration 0261, Issue No. 03
Source Page
5
Medium / Condition
Service Location
TISI 0261 — Permanent
Reference Equipment

Calibration Process

From quotation request to delivery

01

Request

02

Quotation

03

Receive Instrument

04

Calibration

05

Quality Review

06

Certificate

07

Delivery

FAQ

Calibration Questions

Which humidity instruments can SK calibrate?+

Review the instrument list and capability table on this page, or contact our team to confirm the model and range.

What is required for a quotation?+

Please provide instrument type, brand, model, range, required points, quantity, service location and required completion date.

Official Accreditation

Verified governing documents

These official accreditation documents define the verified calibration capability for this service.

Status

Active

Accreditation Programs

TISI 0261

TISI 0261

Actions

Ready to calibrate?

Request a humidity calibration quotation

Send your instrument details and required schedule. Our team will confirm the applicable capability.

Request Quotation